Features Trilight LED Fan on the back panel (Blue, Red, Green) This specification defines the performance and characteristic for 400W Dual Fan Power Supply. 2. DIMENSION: (DxWxH) 5.7"x5.9"x3.3" / 145x150x86(mm) 3. AC INPUT:3-1. AC Input:95~132 VAC or 190~264 VAC select switch,88~264VAC w/active PFCversion(optional)3-2. Frequency: 47HZ to 63HZ3-3. Input Current:10A maximum (RMS) at 115VAC, 6A maximum (RMS) at 230VAC3-4. Inrush Current:35A maximum at 115VAC, 70A maximum at 230VAC 4. DC OUTPUT:4-1. DC Output: Voltage Min.Current Max.Current Peak Current Ripple +3.3V 0.3A 26.0A 28.0A 50mVp-p max. +5V 0.1A 40.0A 52.0A 50mVp-p max. +12V 0.0A 17.0A 22.0A 120mVp-p max. -5V 0.0A 0.5A 0.8A 50mVp-p max. -12V 0.0A 0.8A 1.0A 120mVp-p max. +5V SB 0.0A 2.0A 2.5A 50mVp-p max. ( + 5V and +3.3V combined output 220W )( + 5V and +3.3V and +12V combined output 380W ) (Peak Current is limited to total duration of 60 seconds) 4-2. Output Regulation:+ 3.3V +/- 5% Max. + 5V +/- 5% Max. + 12V +/-5% Max.(Normal Condition) -5V +/- 10% Max. -12V +/- 10% Max. + 5VSB +/- 5% Max. 4-3. Line Regulation: +/- 1% maximum at full load 4-4. Overshoot And Undershoot:The output voltage has no overshoot or undershoot during turn-on or turn-off the power supply 4-5. Overload And Short Protection:All DC outputs are protected from overload circuit and short circuit condition 4-6. Overvoltage protection:All DC outputs will be reduced to zero if the output voltage threshold is exceeded.The overvoltage threshold of +5V output is between 5.8V to 6.3V The overvoltage threshold of +12V output is between 14V to 17V The overvoltage threshold of +3.3V output is between 3.6V to 4.2V 5. GENERAL SPECIFICATION:5-1. Efficiency: 70% minimum at 115VAC , 400W output5-2. Operation Temperature: 0 ~ 50 degree C5-3. Storage temperature: -25 ~ 85 degree C5-4. Humidity: Operating: 20% To 80% RH, Storage: 10% To 90% RH5-5. Hold Up Time:All output voltages will stay within regulation for at least 16.6ms after an AC line voltage failure is detected at nominal line (115 VAC or 230 VAC) under full load condition.5-6. Withstand Voltage:2200VDC between input and ground for 1 minute Power-down Warming Both +5V output voltage and AC input voltage are sense and logical signal.The power good signal is pulled to TTL compatible high level for normal operation and low level for faulty condition. The AC fail signal will cause the power good signal going to a low level in 1 millisecond advance the DC output fall below the regulation limits. The operating point is used as a reference for measuring the1 millisecond as normal operation between minimum and maximum loading.
© Copyright 2003 - 2006 PHPC Online All rights reserved. All prices are subject to change without notice.PHPC Online is not responsible for typographical errors. All typographical errors are subject to correction.By using this site, or ordering from it, you acknowledge that you have read, understood,and agree to be bound by our policies. Please review our terms and policies, thoroughly.
Problem with this web site? Contact the webmaster.
Links