|
|
|
|
 |
Retail Price: $99.00 |
| Our Price: $89.99 |
|
CoolMAX 470W Aluminum w/ Trilight LED fan Item#: CM470ALED |
Usually ships in 24 hours |
 |
|
 |
|
 |
Click the thumbnails below to enlarge |
|
Features Trilight LED Fan on the back panel (Blue, Red, Green) Triple ball-bearing fans design, long life, noiseless and fastest cooling time. Fan speed control adjustable function. (Auto, Middle and Lower Speed) Fan speed monitor function for new M/B. High quality gold-coated fan guard & connectors Tube-tide design and tidy your wires. Over voltage protection, short circuit protection on all output levels. +5V stand by 3A, the largest current in the market. Fully support all Intel & AMD series demand 1. SCOPE: This specification defines the performance and characteristic for model of CT-470 P4 Power Supply. 2. DIMENSION: (DxWxH) 6.4"x5.9"x3.3" / 163x150x86(mm) 3. AC INPUT: 3-1. AC Input: 95~132 VAC or 190~264 VAC select switch,88~264VAC w/active PFCversion(optional) 3-2. Frequency: 47HZ to 63HZ 3-3. Input Current: 12A maximum (RMS) at 115VAC, 6A maximum (RMS) at 230VAC 3-4. Inrush Current: 35A maximum at 115VAC, 70A maximum at 230VAC 4. DC OUTPUT: 4-1. DC Output: Voltage Min. Current Max. Current Peak Current Ripple +3.3V 0.3A 26.0A 28.0A 50mVp-p max. +5V 0.1A 47.0A 54.0A 50mVp-p max. +12V 0.0A 28.0A 32.0A 120mVp-p max. -5V 0.0A 0.5A 0.8A 50mVp-p max. -12V 0.0A 0.8A 1.0A 120mVp-p max. +5V SB 0.0A 2.0A 2.5A 50mVp-p max.
( + 5V and +3.3V combined output 235W ) ( + 5V and +3.3V and +12V combined output 450W ) (Peak Current is limited to total duration of 60 seconds) 4-2. Output Regulation: + 3.3V +/- 5% Max. + 5V +/- 5% Max. + 12V +/-5% Max.(Normal Condition) -5V +/- 10% Max. -12V +/- 10% Max. + 5VSB +/- 5% Max.
4-3. Line Regulation: +/- 1% maximum at full load 4-4. Overshoot And Undershoot: The output voltage has no overshoot or undershoot during turn-on or turn-off the power supply 4-5. Overload And Short Protection: All DC outputs are protected from overload circuit and short circuit condition 4-6. Overvoltage protection: All DC outputs will be reduced to zero if the output voltage threshold is exceeded. The overvoltage threshold of +5V output is between 5.8V to 6.3V The overvoltage threshold of +12V output is between 14V to 17V The overvoltage threshold of +3.3V output is between 3.6V to 4.2V 5. GENERAL SPECIFICATION: 5-1. Efficiency: 70% minimum at 115VAC , 470W output 5-2. Operation Temperature: 0 ~ 50 degree C 5-3. Storage temperature: -25 ~ 85 degree C 5-4. Humidity: Operating: 20% To 80% RH, Storage: 10% To 90% RH 5-5. Hold Up Time: All output voltages will stay within regulation for at least 16.6ms after an AC line voltage failure is detected at nominal line (115 VAC or 230 VAC) under full load condition. 5-6. Withstand Voltage: 2200VDC between input and ground for 1 minute Power -down Warming Both +5V output voltage and AC input voltage are sense and logical signal.The power good signal is pulled to TTL compatible high level for normal operation and low level for faulty condition. The AC fail signal will cause the power good signal going to a low level in 1 millisecond advance the DC output fall below the regulation limits. The operating point is used as a reference for measuring the1 millisecond as normal operation between minimum and maximum loading.
|
 |
|
This product was added to our catalog on Monday October 27, 2003. |
|
 |
Reviews |
 |
 |
 | | There are currently no product reviews. |
|
|
|  |
|
|